Kit MAbtrap, Cytiva, 17 - 1128- 01,pkg de 1 kit

Code: GE17-1128-01 D2-231

Non disponible en dehors du Royaume-Uni et de l'Irlande

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Application

MAbTrap® Kit is an a...


 En savoir plus

Votre prix
$615.21 EACH

Non disponible en dehors du Royaume-Uni et de l'Irlande

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Application

MAbTrap® Kit is an affinity chromatography kit for fast and effective purification of monoclonal and polyclonal IgG from ascites fluid, serum, and cell culture supernatants. MAbTrap® Kit contains everything necessary to perform a complete one step purification without using complicated equipment. It also eliminates time-consuming buffer preparation and column packing. The kit includes one HiTrap® column, prepacked with Protein G Sepharose® High Performance.

Features and Benefits

Convenient kit for purification of IgG from monoclonal and polyclonal material using a syringe in less than 15 min. Kit contains one HiTrap® Protein G HP column prepacked with Protein G Sepharose® High Performance and enough buffer concentrate for 20 preparations with a syringe. MAbTrap® Kit contains everything necessary to perform a complete one-step purification without using complex equipment.

General description

MAbTrap® is an affinity chromatography kit, with everything required for small-scale IgG purification from ascites fluid, serum, and cell culture supernatants.

Legal Information

MAbTrap is a registered trademark of Cytiva

Sepharose is a registered trademark of Cytiva

HiTrap is a registered trademark of Cytiva

avg. part. size34 µm
bed size7 mm × 25 mm
bed volume1 mL
capacity>1 mg binding capacity (lgG/column)(The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)
cleaning2-9(pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.)
column I.D.7 mm
manufacturer/tradenameCytiva 17-1128-01
matrixhighly cross-linked 6% agarose
packagingpkg of 1 kit
parameter﹤4 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.), 42 psi
shelf lifePlease be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
storage condition(20% Ethanol)
storage temp.2-8°C
working range3-9(pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.)