Colonnes de détartrage hitvet, Cytiva, 17 - 1408 - 01, paquet de 5 x 5 mL

Code: GE17-1408-01 D2-232

HiTrap Desalting are ready-to-use 5mL columns prepacked with Sephadex G-25 Superfine resin for fast and convenient desalting and buffer exchange.

HiTrap Desalting are ready-to-use 5mL columns prepacked with Sephadex G-25 Superfine resin for fast and convenient desalting and buffer exchange.

  • Convenient desalting and buffer exchange of sample volumes up to 1.5mL
  • Two to five columns can be connected in series for sample sizes from 3mL to 7.5mL
  • Replaces dialysis for desalting protein, which saves time and reduces labour
  • Requires less than one minute with typically > 95% recovery.
  • HiTrap column format is convenient for use with a syringe, a peristaltic pump, or a chromatography system

HiTrap Desalting is a prepacked, ready-to-use column for group separation between high and low molecular weight substances. Applications include buffer exchange prior to or after different chromatographic steps, removal of low molecular weight contaminants, or removal of reagents to terminate a reaction.

The special design of the column, together with the well-known resin Sephadex G-25 Superfine, provides fast and reproducible separations in a convenient format.

The exclusion limit is approximately Mr 5000. This ensures group separation of proteins/peptides larger than Mr 5000 from smaller molecules.

Separations are easily performed with a syringe, a pump, or a chromatography system such as an ÄKTA system.

packagingpack of 5 × 5 mL
particle size﹥20 µm (dry)
working range2 - 13
bed volume5 mL
column I.D.16 mm
bed size16 mm × 25 mm
cleaning2 - 13
storage conditiondry media
mfr. no.GE Healthcare, 17-1408-01
shelf lifePlease be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
parameter≤15 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)
parameter42 psi
matrixcross-linked dextran
suitabilitysuitable for bioprocess medium
Cas Number64-17-5
Hazard Class3
Un Number1170
Pack GroupII
Ce produit répond aux critères suivants pour être admissible aux récompenses suivantes :



HAVE AN ACCOUNT? LOGIN

GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.