Colonne HPLC d'Exclusion taille TSKgel (Type H ), phase GMHxl- l, l x i.d. 30 cm x 7,8 mm, taille des particules 6 mum

Code: 816652 D2-0

Non disponible en dehors du Royaume-Uni et de l'Irlande

Compatibility

THF can be replaced with acetone, ethanol, quinoline, benzene, o-dichlorobenzene, ethyl acetate, dodecane, FC-113, carbon tetrachloride, trichloroethane, n-hexa...


 En savoir plus

Votre prix
$3,227.83 EACH

Non disponible en dehors du Royaume-Uni et de l'Irlande

Compatibility

THF can be replaced with acetone, ethanol, quinoline, benzene, o-dichlorobenzene, ethyl acetate, dodecane, FC-113, carbon tetrachloride, trichloroethane, n-hexane, cyclohexane, xylene, tetrahydrofuran, chloroform, 1,4-dioxane, hexafluoroisopropanol, toluene, 1-chloronaphthalene, dimethylaceto acetamide, methyl ethyl ketone, trichlorobenzene, m-cresol, dimethylformamide, methylpyrrolidone, o-chlorophenol/chloroform, dimethyl sulfoxide, pyridine

General description

TSKgel GMHXL-L mixed-bed columns are packed with a mixture of rigid, polymer beads, varying in average pore size, for the analysis of organic-soluble industrial polymers. Mixed bed or linear columns are used when a broad range of polymer molecular weights is expected in the sample. This column gives high resolution of polymers with a molecular weight up to about 100,000 Da, although the exlusion limit is higher. The shipping sovent THF can be replaced by benzene, chloroform, toluene and xylene, but not with dichloromethane and dichloroethane. As the number of solvents that can be exchanged directly with the shipping solvent is limited, use TSKgel Hhr-type columns when a broader range of organic solvents is needed.

Legal Information

TSKgel is a registered trademark of Tosoh Corporation

Physical form

Shipped in THF.

Recommended products

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

agencysuitable for USP L21
L × I.D.30 cm × 7.8 mm
manufacturer/tradenameTosoh 16652
materialstainless steel hardware
matrix active grouppolystyrene-divinylbenzene phase
matrixpolymer particle platform
parameter1.2 mL/min flow rate, 35 bar max. pressure, 80 °C temperature
particle size6 µm
pore sizemixed
product lineTSKgel®
separation techniquesize exclusion (SEC)
technique(s)HPLC: suitable