TCLP Metals in Soil - PT,

Code: SPE005-225G D2-231

Not available outside of the UK & Ireland.

Application

TCLP Metals in Soil - PT is a soil/hazardous waste proficiency testing material, suitable for testing TCLP metals in soil samples.Our soil PT samples behave as re...


 Read more

Your Price
$435.21 225G
Discontinued

Not available outside of the UK & Ireland.

Application

TCLP Metals in Soil - PT is a soil/hazardous waste proficiency testing material, suitable for testing TCLP metals in soil samples.Our soil PT samples behave as real samples; and, unless there is no alternative, are not simply spikes added to a blank soil. They are designed to meet the requirements of national, regional and state-specific accreditation bodies (TNI, USEPA, UKAS) for quality assurance and continuous improvement.Have any questions? Explore our FAQs.For more information on this product, please contact our PT Service Team.

Features and Benefits

We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.Our proficiency testing (PT) program is a benchmark to: provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process provide a comparison of performance with that of other laboratories, nationally and internationally test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems provide an independent evaluation of laboratory performance demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

General description

TCLP Metals in Soil proficiency testing material is produced in accordance with ISO/IEC 17043:2010. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. We are the world leader in the manufacturing of real-world soil and sediment PT products.Type of PT Scheme: Solids/Soils/Hazardous WasteMatrix: SoilAnalyte/s: Values of analytes vary lot to lot.All information regarding the use of TCLP Metals in Soil - PT can be found in the reporting packet which will be available to download at PT Portal.

Legal Information

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

Other Notes

Are you new to Supelco® Proficiency TestingͰ Be sure to register your account details in the PT Portal before placing your order.This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at [email protected] placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.Proficiency Testing Schedule (2022-2023)SoilsLPTP22-S2 April 6 - May 20, 2022LPTP22-S4 October 5 - November 18, 2022LPTP23-S2 April 5 – May 19, 2023LPTP23-S4 October 4 – November 17, 2023Quick-Turn Study (on demand proficiency test that is offereddepending on lot availability)

Preparation Note

Description The PT sample is suitable for analysis for the eight TCLP metals. A total sample size of 225 g is provided. The PT sample has been sterilized. Once opened sample should be used within 6 months or by the expiration date on the label, whichever is sooner. The evaluation of results will be based on study statistics for equivalent methods. At least two analytes are above the regulatory limit. Some analytes may not be present at recoverable levels.Sample Preparation Extraction Procedure: Thoroughly mix the sample and extract an accurately weighed portion (approximately 100 grams) of the material using SW846 Method 1311; Toxicity Characteristic Leaching Procedure. Prepare the extract for metals analysis by using the appropriate digestion procedure for the analysis technique selected. The sample may be analyzed by any combination of inductively coupled plasma (ICP) and atomic absorption (AA) methods. Provide all the requested information. Do not correct the analytical results for matrix spike recovery bias. Digestion Procedures: Prepare the TCLP extracts for metals analysis using the methods for which you are seeking accreditation. There is sufficient TCLP extract to perform all digestions. If a sample digestate contains particulates that may clog your instrument, remove them by filtration, or by centrifugation (see appropriate method for guidance). Analyze the digestate solutions using the appropriate determinative methods for which you are seeking accreditation. The method used must be reported for each analyte.

Storage and Stability

Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.

application(s)environmental
formatmatrix material
matrixsoil
packagingpkg of 1 × 225 g
Quality Level100
This product has met the following criteria to qualify for the following awards:



HAVE AN ACCOUNT? LOGIN

GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.